• Heating Pipe Sizing in Netsys - Emitter Queries

    Sebastian Mlynarski
    Sebastian Mlynarski
    Hi, Its been a while since the last time I used Hevacomp so apologies if the questions seem trivial. I am trying to model a relatively large project, I have already placed all my emitters (some ceiling void, some floor level). When I try to connect…
    • over 1 year ago
    • Hevacomp
    • Hevacomp Forum
  • Hevacomp to openbuilding designer. Heating, gas, Hot and cold pipework design.

    Paul Jacob
    Paul Jacob
    As i understand. Bentley Hevacomp is being retired and replaced with openbuilding designer. I cannot find any training for openbuilding designer to do with plumbing systems. Only ductwork ventilation systems. I would like to know how to design a heating…
    • over 2 years ago
    • Hevacomp
    • Hevacomp Forum
  • New Pipework type for Netsys, Heating

    Rey Andrew Gatmaitan
    Rey Andrew Gatmaitan
    Hi, Is it possible to have a new pipework type on NETSYS, heating? I need to use the attached details below for the modelling. Please refer to the attached file for reference. PDF Please, if you have other resources that you use with this type…
    • over 3 years ago
    • Hevacomp
    • Hevacomp Forum
  • Could you please provide details on how Hevacomp calculates system contents on both cooling and heating systems ?

    Neil Rooney
    Neil Rooney
    I would like a break down of what hevacomp uses for calculating system water contents on heating and cooling systems.
    • over 5 years ago
    • Hevacomp
    • Hevacomp Forum
  • Heating and Chilled water - Excessive pressure drop

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: N/A Overview Excessive pressure drops can occasionally be seen on Heating and Chilled Water networks…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Heating and Chilled water - Higher than expected flow rates

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i Environment: N/A Area: Netsys Subarea: Pipe Sizing Overview When considering pipe sizing of LPHW and CHW systems, mains losses must…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • Pipe sizing - Water content for heating and cooling emitters

    Duncan Brown
    Duncan Brown
    Product(s): Hevacomp Mechanical Designer Version(s): V8i (N/A) Environment: N/A Area: N/A Subarea: N/A Overview The water content calculation for Netsys Heating and Chilled Water schematics…
    • over 5 years ago
    • Hevacomp
    • Hevacomp Wiki
  • RE: de-active snap grid

    Shane Regan
    Shane Regan
    Hi Arun, you can change this setting by going to Pipes > Defaults, and deselecting the Snap Grid option. Also, if you wish to change the Ortho settings you can do so by going to Defaults>Ortho. You can see this operation if you view this document .
    • over 7 years ago
    • Hevacomp
    • Hevacomp Forum
  • Netsys Heating Sample Project

    Duncan Brown
    Duncan Brown
    Netsys Heating Sample Project - unzip into new folder and open with the Netsys Heating program
    • SAMPLEHEATING.zip
    • over 7 years ago
    • Hevacomp
    • Hevacomp Files