I have a couple storm sewer utility runs drawn.
Where one of my nodes have 3 different conduits connect too, in the properties how ever it only shows one
connecting link. I'm attempting to resolve this so i can annotate all of the connecting conduit…
Hello,
I'm using ORD Drainage and have a model fully set up. However, when I compute a Design scenario, the last pipe leading to the outfall always gets assigned strange inverts. Here's a screenshot of the profile run of the one of the main trunklines…
Hello,
I have a structure that will have both communication and electrical conduits connected to it. Unfortunately the different Network Types within the feature definitions do not let this happen. Can anyone point me to more information regarding…
Good day,
I'm using OpenRoads Designer 2020 Release 3.
How do I set the conduit Length (construction) (m) to be equal to Length (User Defined) (m)?
i.e. I cannot type in a length while the conduit is active, I have to move the headwall node to…
Please may I get assistance with assigning a baseline feature to a conduit. I'm using Open Roads Designer 2020 Release 2 (10.08.01.33)
I've managed to assign the node to the baseline feature RampB.
I would like to achieve the same for a conduit. Get…
In Subsurface Utilities, I am trying to create a flex table that includes the stations (stakevalues) of the respective conduits.
My baseline is annotated, however, I cannot seem to link that to the centreline of the conduit.
Please may I get some…
Hello,
I'm using Subsurface Utility Design And Analysis V8i.
I've created new conduit as explained on this video .
I linked the new conduit between two nodes. At first the element information sections looks like this:
/resized-image/__size/190x787…
Hi All,
I'm defining a duct which is 0.17 x 0.15 m for total size in cross-section with a thichness of 2.5 cm. When enter this dimension in Feature-definition as "box", SUE changes it to 0.2 x 0.2 m and the moduled 3D-duct is also too big (i.e. 0.2…
Hi all. I have created a box shaped conduit (duct), and have input the minimum bend radius, minimum cover etc. When I extract utilities from graphics (extracting from a 2D linestring and using a terrain model for elevation), the conduit is clearly not…
Hi all. I was wondering if anyone had an idea on how I would be able to create a fitting or joint in SUE, where a square conduit connects with a cirkel conduit. Both are placed by center, but I can't get my head around how I would create the cell for…