• Bentley i-model Composition Server Processors Increase

    Ludovick
    Ludovick
    Dear, i have an existing i-model server installed as Standart (SS4 590 on windows 2008 r2) How can i increase numbers of processors and especially Iplot Processors (as i can configure with custom install) on my existing environment without reinstalling…
    • over 5 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • Monitor number and /or Age of imodel Jobs

    Ludovick
    Ludovick
    Dear all, Sometimes, one job stuck in PJW imodel server then no job can execute until job is removed Is there a way to monitor number of jobs waiting and/or the date of the oldest job ? in pwshell, or any method best regards Ludovick LAGREVOL…
    • over 5 years ago
    • ProjectWise
    • ProjectWise Publishing Forum
  • Full text Indexing of more than 1 Million Files in same datasource failed PJW SS4 590

    Ludovick
    Ludovick
    Hi, On one of my biggest datasource we have more than 1 Million Files, With full text indexation , Pjw create text files with guid of the document on folders (one by datasource) which then are process by microsoft search server FTR extraction seems…
    • over 6 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • Error - IPENGINE, Fatal error, iplotdrv failed to complete. - Milepost code: 7100

    MichaelGilham
    MichaelGilham
    Hello All, I'm hopeful you can assist in decoding (or resolving) an issue we are currently encountering. We are receiving the error shown in the title line. The full error reads as such: Failed -- Failed to create plot set: IPLOTSRV-E-DGNFILE, Error…
    • over 8 years ago
    • ProjectWise
    • ProjectWise Publishing Forum
  • Trimble Business Center connection

    J03 C:\
    J03 C:\
    Trimble Experts- I am attempting to add an External Service to Trimble business center. It says that you can connect ProjectWise but gives no instruction. The values it is looking for are below. I have entered in my web server address, my user as well…
    • Answered
    • over 8 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • ProjectWise V8i SS4 Integration Compatibility List Update

    JackiS
    JackiS
    The ProjectWise V8i Integration Compatibility List has been updated. You may also find this information in the corresponding readme files delivered in the individual product specific download. The ProjectWise CONNECT Edition Compatibility list can be…
    • over 8 years ago
    • ProjectWise
    • ProjectWise Design Integration Blog
  • EML Indexing

    J03 C:\
    J03 C:\
    Morning All- I was wondering if anyone has been able to index .EML files. I know ProjectWise does .MSG files but won't do eml from what I read. I have tried indexing them as msg files but no dice. Anyone have any info? The files contain the required…
    • over 9 years ago
    • ProjectWise
    • ProjectWise Design Integration Forum
  • PW InterPlot Server SS4

    Joerg Teresniak
    Joerg Teresniak
    Is TR# 268106 fixed in ProjectWise InterPlot Server 08.11.11.34 ?
    • over 11 years ago
    • ProjectWise
    • ProjectWise Publishing Forum
  • View related content from anywhere
  • More
  • Cancel