• During a calculation some plastic points disappear. How is that possible?

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D PLAXIS 3D Date created 28 March 2013 Date modified 28 March 2013 A point is denoted as plastic failure point if it is currently on the failure envelope (e.g. Mohr…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • In Plaxis Curves it is possible to plot Force Fx, Fy and Fz. What are these parameters?

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D PLAXIS 3D Date created 26 May 2014 Date modified 26 May 2014 The parameters Force Fx , Fy , and for PLAXIS 3D Fz , are the total reaction forces of the applied prescribed…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • After a consolidation analysis I have excess pore pressures in "drained" material sets. Why?

    Micha van der Sloot
    Micha van der Sloot
    Application PLAXIS 2D PLAXIS 3D Version PLAXIS 2D PLAXIS 3D Date created 24 April 2013 Date modified 24 April 2013 The material type setting Drained , Undrained A and Undrained B refers to a plastic, dynamics and…
    • over 3 years ago
    • GeoStudio | PLAXIS
    • GeoStudio | PLAXIS Wiki
  • View related content from anywhere
  • More