Everytime we try to output a fence a BOLD message is displayed across the the preview / pdf that reads "You should update your software". After uninstalling and re installing the gINT software the message is still there. We are using version 10.01.00…
Dennis,
You define the non-standard groups and headings in the DICT table in your gINT database.
For example, here are some of the fields in the DICT table from a gINT database.
The example data below is actually from an AGS3 database that I…
Hi Tom,
Yes.
You need to enter a numeric value.
4 or 4.0 will be interpreted the same.
But, AGS4 will NOT be interpreted as 4 or 4.0, so you will get a version 3 AGS file created during export.
It would be the same as if you left the field…
Dennis,
The AGS4 file that gets created when you export from a gINT database will only have the DICT Group if your gINT AGS4 database has non-standard AGS Group and AGS Heading names.
What are you using for your AGS4 gINT database? Did you setup…
It looks like an update broke BMP symbols printing on log reports. Anybody else having the same problem? Some of our users have older versions and the BMP prints fine, but in 08.30.03.77 it's not working
Calan,
The TRAN_AGS field in the TRAN table in your project database is used to specify the version of the AGS file that will be created during export. If that field does not exist, or is blank, then the AGS version is taken as v3.
Also, did you…
Dennis,
Again, there will only be a DICT section in the exported AGS file if you have Groups or Headings in your database that are non-standard.
With AGS3 and gINT there were many fields and some tables in the gINT AGS database there were non-standard…