• Unable to load/create dialog item of type 'IconCmd', id = 40101 from dialog/task "/USTN"

    keep calm
    keep calm
    Dear All, when I am open the microstation... appears warning " Unable to load/create dialog item of type 'IconCmd', id = 40101 from dialog/task "/USTN" ..... how to fixed it..? please your advice..
    • 8 days ago
    • Product Administration
    • Product Administration Forum
  • Openxxxxx Client Workspace Configuration Redeployment Stress Test

    Matt Bombace
    Matt Bombace
    I Folks- I am looking to see if any admins out there are doing any pre-configuration-deployment "Stress Test" (I had in mind similar to a Software Test Plan procedure) on their Client Configs prior to releasing them to projects for production work? …
    • 1 month ago
    • Product Administration
    • Product Administration Forum
  • [MSTN 2023/ORD] Multiple results for one variable

    lilsweepr
    lilsweepr
    Trying to figure out how to display the results of a variable that points to 2 different locations within the same "select" dialog box. Or asking if it is even possible. specifically - MS_PENTABLE One line is set like this - MS_PENTABLE < $(CIVIL_ORGANIZATION_STANDARDS…
    • 1 month ago
    • Product Administration
    • Product Administration Forum
  • What is the best procedure for loading a client's workspace in CONNECT?

    William Spagnoli
    William Spagnoli
    Just received configuration files and design information from a new client. It's been a while since I've had to handle this task. I'm early in the process, but I'm wondering the basic procedure for loading a new workspace. Not having any luck stumbling…
    • Answered
    • 4 months ago
    • Product Administration
    • Product Administration Forum
  • Workspace / workset changing when file opened

    Michael Reilly
    Michael Reilly
    We've got a file that needs to be opened in the correct client build (Build A). We start CAD (Connect edition MS 16, OB 10), select Build A, browse to the file, and open it. When CAD finishes opening it is in a different build (Build B). There are…
    • 9 months ago
    • Product Administration
    • Product Administration Forum
  • Unable to verify my e-mail address

    Aischa Amrhein
    Aischa Amrhein
    This is my back-up account. I am a teacher, I use MicroStation in my course. I want to verify my school e-mail address, so that I can have access to the full academic MicroStation version. However, every time I try to login, the screen appears informing…
    • 11 months ago
    • Product Administration
    • Product Administration Forum
  • A better way to debug MDL loader error 127

    Lubo B
    Lubo B
    Hello guys, is there a way to access some kind of Microstation log when user encounters MDL loader error "OS could not load xx.dll" (error 127) ? Or do I need to manually find out with applications like ProcessMonitor? I was wondering, maybe Microstation…
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • 'File' Dialog Is Extremely Slow

    Ben Goble
    Ben Goble
    Hi All, We have recently moved over from V8i SS3 Microstation to Powerdraft Connect. We have found that the 'File' dialog (below) appears to be very slow. Obviously, with the frequency we use this dialog, it is having a cumulative impact on our work…
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • I have a user who is not getting read only messages when opening a file another user is in, and other users are able to open a file the one user is in with no read only message. This has lead to file corruption. Is there a setting for this?

    Dale Wozniarski
    Dale Wozniarski
    Read Only message not displaying
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • Power GEOPAK V8i - Can't Open Macro File

    Hart Weatherford
    Hart Weatherford
    In trying to setup both SCDOT and NCDOT workspaces in my Microstation GEOPAK, I've caused an issue that I can't seem to fix. When I start MS, this window opens with the mesasge "can't open macro file [C:\Program files (x86)\Bentley\PowerGEOPAK V8i (SELECTseries…
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • [MicroStation CONNECT] Is MicroStation certified for use with VMware?

    Jon Summers
    Jon Summers
    Is MicroStation certified for use with VMware in a Windows network?
    • Answered
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • [CONNECT U14] PW level library attach keyin

    Chris Dixon
    Chris Dixon
    Using PW CONNECT and Integrated MicroStation CONNECT. I want to attach a library file (dgnlib) through a keyin - this keyin can then be used with a custom button trying to locate a file within PW, the same keyin works if the file exists on an external…
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • Status of Enhancement #961901 (WorkSet Mismatch Issue) and Bentley's Course of Action?

    glhouck
    glhouck
    We were wondering what kind of progress has been made on providing options for the WorkSet Mismatch issue, and what sort of solution Bentley is pursuing? We do * not * want the WorkSet Mismatch notification simply turned off. We typically want the currently…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • [MicroStation CONNECT Ed. U13] MS_DGNAPPS

    Daniel Grohmann
    Daniel Grohmann
    The <MS_DGNAPPS> configuration variable is predefined and filled with following string: "$(IP_IPLOT)\bin\iplotn.ma;CifDWGExportManager;Bentley.StatusCursorPrompt" on system and application level. In order to optimize the licences in use of our organization…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • DGN File name as a text string in microstation version 7 drawing

    Bhushan Bharatrao Kubde
    Bhushan Bharatrao Kubde
    We have isometric drawings extracted from Intergraph PDS in microstation version 7. As a part of title block, we need to Display the file name on isometric title blocks. Any suggestions on how to achieve this. Thanks Bhushan
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • MicroStation V8i and MicroStation Connect Concurrent Installations

    John Garrison
    John Garrison
    Can you have both MicroStation V8i (SS4) and MicroStation Connect installed on the same machine concurrently? Thanks, John
    • Answered
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • Custom tool box - where is the Delete tool?

    Kelly Ogle
    Kelly Ogle
    I have the perfect custom toolbox except it is missing the delete tool. Where do I find that in the list of tools? Thanks I just created a new tool. The command is: delete.
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • if else in a CFG file

    Nico Caspel
    Nico Caspel
    how can I use the below in a .cfg file % if $ (USERNAME) == "nvancaspel" || $ (USERNAME) == "bpunt" % if exists ($ (_ MS_CONFIG_HOORN_COF) Optimize_admin_CE.cfg) % include $ (_ MS_CONFIG_HOORN_COF) Optimize_admin_CE.cfg else % if exists ($ (_ MS_CONFIG_HOORN_COF…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • Microsation J on Windows10

    Matthew Ang
    Matthew Ang
    HI, we are using a legacy software that is running in Microstation J, unfortunately the developer is already gone it is still working as of this writing. But We are concerned if Microstation J will still be supported in the future. I would like to confirm…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • Latest update - Workspace/Workset inaccessible.

    B.Chalker
    B.Chalker
    The latest update has rendered all my networked Workspaces/Worksets inaccessible. Is there a setting somewhere I need to enable to undo this, or am I stuck rebuilding it all AGAIN?
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • [MicroStation CONNECT Ed. u13] _USTN_LOCALE_LANGUAGE

    Rob.G
    Rob.G
    _USTN_LOCALE_LANGUAGE is a predefined and locked variable. According to recommendations I'm using this var to set some configuration issues. Now I have computers on which my config does not work as the variable points to 'de', although the application…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • SCDOT Workspace for Microstation and Geopak

    Cynthia Bohannon
    Cynthia Bohannon
    SCDOT provides a number of downloads on their CADD Design website ( https://www.scdot.org/business/CADD-Design.aspx ) that are intended for contractors use. I have downloaded the “Complete Microstation and Geopak Workspace” .exe file and have been attempting…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • MicroStation Connect 12 - I have lost all the larger size ribbon icons, most appear to be the small version, in ribbon customize I have selected large icon, but they continue to display as small icons. This is from an update from version 11 to 12 (wo...

    patch
    patch
    MicroStation Connect 12 - I have lost all the larger size ribbon icons, most appear to be the small version, in ribbon customize I have selected large icon, but they continue to display as small icons. This is from an update from version 11 to 12 (working…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • Multiple users are able to open the same .dgn at the same time without MicroStation PoweDraft recognising it as being already open. Files are on a QNAP NAS.

    Nuwan Gunawardena
    Nuwan Gunawardena
    Multiple users are able to open the same .dgn at the same time without MicroStation recognising it as being already open - the file is NOT being flagged as read-only. Files are stored on a QNAP NAS. Any ideas?
    • Answered
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • How to find out what is stored in a DGNlib

    PH
    PH
    On configuring a Workspace and Workset for MicroStation CONNECT Edition I got stuck in a hugh number of textstyles, dimstyles, linestyles, named expressions and more, being left-overs from a long history in the customers V8i workspace. There are many…
    • Answered
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • View related content from anywhere
  • More
  • Cancel
>