• Long term support version

    Mick Inkster
    Mick Inkster
    I recently asked whether Bentley could implement a long term support version for their desktop applications. The response I got was a link to their web page about their current lifecycle policy which shows that desktop applications (MicroStation, Open…
    • 4 months ago
    • Product Administration
    • Product Administration Forum
  • I have a user who is not getting read only messages when opening a file another user is in, and other users are able to open a file the one user is in with no read only message. This has lead to file corruption. Is there a setting for this?

    Dale Wozniarski
    Dale Wozniarski
    Read Only message not displaying
    • over 1 year ago
    • Product Administration
    • Product Administration Forum
  • How to load a custom UCF at startup of Microstation CE/OpenCities Map application.

    Lubo B
    Lubo B
    Hello everyone, I have a question regarding loading custom UCF file during the startup of Microstation CE application(and also OpenCitiesMap/Advanced, OpenCities Map Ultimate). Back in the days of V8I, there was an option to launch the Microstation…
    • Answered
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • custom detailing symbols - incorrect default variable

    chris Cher
    chris Cher
    I made custom detailing symbols and custom drawing seeds at a workset level and i noticed that variables are not properly configured by default: MS_DGNLIBLIST_DRAWINGSEEDS is OK $(_USTN_WORKSETSTANDARDS)Dgnlib\DrawingSeed*.dgnlib $(_USTN_WORKSPACESTANDARDS…
    • over 2 years ago
    • Product Administration
    • Product Administration Forum
  • Network install of MicroStation CE, Rel 14, "Configuration" folders.

    RKoons
    RKoons
    I finally have come to a point where I believe I know what is happening; I just need to better understand why, and if anybody else has seen this issue. In short, I am under the gun, trying to get ready for the end of year fun where SS4 goes "away",…
    • over 3 years ago
    • Product Administration
    • Product Administration Forum
  • [CE] Named Expression for analyzing the Connection Username, Group, ...

    Daniel Grohmann
    Daniel Grohmann
    I 'd like to limit the access to a tool or function with named expressions. The Connection usergroup seems to be a good criteria. Is it possible to evaluate the Connection usergroup of the current connection user? best regards, Daniel
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • [MS CE u13] default reference setting for visible edges

    Rob.G
    Rob.G
    I just noticed that if you drag&drop models into the view or the reference dialog and use the 'recommended' referencing setting the visible edge setting for 3D attachments is now set to 'CachedAlert'. I also found that a new variable MS_REF_VISEDGE_ATTACH_STATE…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • Custom detailing symbol cell dgnlib will not load in projectwise.

    blomstrom
    blomstrom
    Microstation V8i (select series 4) Version 08.11.09.829 I have made custom detailing symbols dgnlib ( they are anotated cells) for our company and placed them in our workspace dgnlib environment in Projectwise, but they do not appear when using the…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • Workset Path: Path does not exist

    Lars MP
    Lars MP
    I am struggling with worksets, and in particular with the Browse button. I get this: Same thing with a brand new workset by clicking Create Workset. I would very much know which path it is, which does not exist. Seems line first line of the alert…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • [CONNECT] Disable Workset Verification

    Daniel Grohmann
    Daniel Grohmann
    Hello everybody, in our organization we work in a workspace/workset configuration within our cad operators have to load/open different dgn files not assigned to any worksets. Is there an environment variable/method/function im CONNECT to suppress…
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • Connect Layout Configuration for Laptop

    Darren Waschow
    Darren Waschow
    When setting up Connect (in this case MicroStation and/or OpenRoads Designer), what's the most effective way to have multiple screen layouts for a laptop. When at the office, the user has three screens (the laptop's and two desktop monitors) but when…
    • Answered
    • over 4 years ago
    • Product Administration
    • Product Administration Forum
  • Ribbon Customization and Tabs

    cswnow
    cswnow
    I wanted to add a few more tabs to the Drawing workflow and it was only allowing me to add one. I created another workflow and was allowed to add more tabs with no problem. My question is: Is there a maximum number of tabs you can have under each workflow…
    • Answered
    • over 5 years ago
    • Product Administration
    • Product Administration Forum
  • Levels Shown as used but I can not find them in the file

    David Sullivan
    David Sullivan
    Good Morning, I have a .dgn file that when I look at the Level Display it list a large number of levels with elements on that level and is used but I cannot see them. I make on active and turn off all the others and fit view and nothing is there. They…
    • over 5 years ago
    • Product Administration
    • Product Administration Forum
  • [MCSE Update 7] _USTN_ROLECFG Not Being Defined in Organization Standards.cfg

    Marty Robbins
    Marty Robbins
    Should the personal.ucf configuration file load prior to the _USTN_ORGANIZATION configuration? If not, the ..\Organization\standards.cfg will not pick up any configuration variables defined in the personal.ucf file. Currently the msconfig.cfg has _USTN_ORGANIZATION…
    • over 5 years ago
    • Product Administration
    • Product Administration Forum
  • Most recently Used (MRU) file list

    David Sullivan
    David Sullivan
    Hello, I am looking to change the number of Most Recently Used files listed under the File > menu item. We are using MicroStation V8i SS2. Thank you for any assistance you can offer. Merry Christmas, David
    • over 5 years ago
    • Product Administration
    • Product Administration Forum
  • RE: Workspaces on different drives on a network

    Rousenator
    Rousenator
    I can get it to work making the following addition to the msdir.cfg (C:\Program Files (x86)\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config): [General] _USTN_INSTALLED_WORKSPACEROOT=Z:\Personal\BSR\Workspace/ # _USTN_INSTALLED_WORKSPACEROOT…
    • over 6 years ago
    • Product Administration
    • Product Administration Forum
  • MS_LEVEL_DO_NOT_SYNCHRONIZE_ATTACHMENT_LEVELS_TO_DGNLIB

    Gary Mansager
    Gary Mansager
    There are several posts relating to this: MS_LEVEL_DO_NOT_SYNCHRONIZE_ATTACHMENT_LEVELS_TO_DGNLIB but none of the documentation links work anymore. Nor is this variable documented. Makes MicroStation issues related to this variable difficult to support…
    • over 6 years ago
    • Product Administration
    • Product Administration Forum
  • Redirect Connect to our server

    cswnow
    cswnow
    I think I got Microstation Connect to redirect to my server. I modified the C:\ProgramData\Bentley\CONNECT Edition\Configuration\WorkSpaceSetup.cfg file to point to my server which contains the file structure: K:\WWE Configuration\ K:\WWE Configuration…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • [CONNECT] Named Expression with Compound condition

    Keith Ouellet
    Keith Ouellet
    Have I done something wrong or is there a problem with Named Expression that contain compound conditions in CONNECT? I have a Ribbon Group that I want to show only when one of two models are active (aplan or Sheet1) I have the two models within my…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • Email to Tech Support Fails

    Brandon Bosch
    Brandon Bosch
    I need help with user and admin accounts; I logged a ticket for this purpose ( Service Request 7000514289 ). I have received emails from a technician, but when I reply, they bounce. I have logged a noted inside the ticket and received a reply, but any…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • Faster Installation Options:

    RKoons
    RKoons
    We are a Chicago company working with the "Latest" versions of the SS4 Geopak. We are driven by our DOT and their workspace, and the associated bugs and issues involved with a major DOT workspace and Geopak / MicroStation. As the one in charge with…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • Silent install of Microstation V8i Series 3

    Jeremy
    Jeremy
    I just wanted to point out that the documentation for the deployment image (Microstation V8i Series 3) is wrong. It states that you can only change the setup to full UI or Reduced UI. I foolishly believed this for a long period of time and set out to…
    • over 7 years ago
    • Product Administration
    • Product Administration Forum
  • v8i - UCF vs PCF

    David Lanham
    David Lanham
    I noticed that if I placed a configuration variable in both the UCF and the PCF, then the UCF was "cancelling" the PCF. In both files, I was using the ">" sign to append the definition. For example, I had MS_MACRO defined in both, using the ">". The…
    • over 8 years ago
    • Product Administration
    • Product Administration Forum
  • Regular Expression test file exist, then drive GUI

    Ivo Blaauw
    Ivo Blaauw
    Here's a question that is actually two questions combined. Before you tell me to post 'm seperately, hear me out first please. Is it possible to have Regular Expressions test for the existence of a certain file? Is it possible to have a tool change it…
    • Answered
    • over 9 years ago
    • Product Administration
    • Product Administration Forum
  • Custom Line Styles in DGNLIB

    cmeuser
    cmeuser
    As I understand it, when we manage our custom line styles from a DGNLIB, when an end-user selects a line style active and places it in a DGN file, that line style definition is now part of the DGN file. Are there any circumstances that would not allow…
    • Answered
    • over 9 years ago
    • Product Administration
    • Product Administration Forum
  • View related content from anywhere
  • More
  • Cancel
>