• "Use corroded thickness in all analyses" model options, edit settings for an AutoPIPE model
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version...
  • 09. Why does the AutoPIPE Vessel calculate different wall thickness for a vertical vessel where one chamber is made with 2 sections of the same material?
    Tanaji Gaikwad
    Question: I am designing a vertical vessel having one chamber which has 2 sections of same material. The corrosion allowance , radiography etc. for the 2 sections are identical, there is no wind or seismic...
  • Error Code 490 - FLAT HEAD: number of opening > 1 ==> out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Error Date Logged & Current Version Aug 2023 43.01.01.011 Problem: The following message appears...
  • 15. How can I change the test pressure for the different lines using AutoPIPE?
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Analysis Date Logged & Current Version Aug. 2023 23.00.00.230 Problem: Hydrotest design pressures are...
  • Q. Change AutoPIPE Edition License to: (Standard, Advanced, Nuclear)
    Mike Dattilio
    Note : a. User must be signed into CONNECTION Client before proceeding below, or have imported a license file with specific entitlements. b. The same exact downloaded file is used by AutoPIPE Standard...