• 02. Why does a BEW heat exchanger designed to CODAP 2005 not calculate to ยง C7.A9.6 (sliding head exchanger)?
    Tanaji Gaikwad
    AutoPIPE Vessel team decided to not apply the Annex C7.A9 for sliding tubesheet because this chapter is not sufficient. There is no rule to determine the thickness of the tubesheet, so we decided to...
  • 01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Calculations Date Logged & Current Version Sept. 2017 40.04.00.08 Problem: Formula for calculation...