• 03. Where to change the values for Clamp Wb and Wba for BS En 13445 2021 using AutoPIPE Vessel?
    Mike Dattilio
    Answer: These values are not user input values or calculated values by the program. These values are referenced by the Allowable Bolt Load table at Room Temp or At Design Temp for the clamped flanges...
  • Error Code 490 - FLAT HEAD: number of opening > 1 ==> out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Error Date Logged & Current Version Aug 2023 43.01.01.011 Problem: The following message appears...
  • Q. What values to use for Crotch Radius and Crotch Thickness on a Welded / Contour tee per ASME B31J in AutoPIPE?
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Modeling Date Logged & Current Version Feb 2023 12.08.04.009 Problem: What values to use for Crotch Radius...
  • 06. Can different support groups access a scaled version of the RS without counting toward the limit of 50 RS per AutoPIPE model?
    Mike Dattilio