• 10. Is it possible to combine S.A.M. load case (S1..S10) with a static seismic load case (E1..E30) in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Load cases Date Logged & Current Version May 2022 12.08.00.063 Problem: Is it possible to combine S.A.M. load case (S1..S10) with a static seismic load…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 22. SAM cases are not included in AutoPIPE's code combination 2Mb2+ 2Mce, only the seismic force are being evaluated, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Cod combinations Date Logged & Current Version Aug. 2021 12.06.00.48 Problem: SAM cases are not included in the 2Mb2+2Mce code combination. Solution:…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 21. Calculate SAM and Expansion stress values independently, and then add these two stress values together in a single combination using AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Jan 2020 12.02.00.14 Problem: Calculate SAM stress values and Expansion stress values independently, and then add these two…