• 22. SAM cases are not included in AutoPIPE's code combination 2Mb2+ 2Mce, only the seismic force are being evaluated, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Cod combinations Date Logged & Current Version Aug. 2021 12.06.00.48 Problem: SAM cases are not included in the 2Mb2+2Mce code combination. Solution:…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 21. Calculate SAM and Expansion stress values independently, and then add these two stress values together in a single combination using AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Jan 2020 12.02.00.14 Problem: Calculate SAM stress values and Expansion stress values independently, and then add these two…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 20. How are the moment results for the selected Combination Method (ex. SRSS, ABS, etc..) calculated in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Nov 2019 12.02.00.14 Problem: How are the moments in the Code Compliance report calculated based on different combination…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 11. How to Disable all Non-code combinations in the analysis and reports in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2016 10.01.00.09 Problem…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 12. How to factor a combination correctly, 1.2G+1.5E in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Sept. 2016 10.01.00.09 Problem…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 06. How to automatically find the MAX load case from a group of load cases in an AutoPIPE model

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE, Version(s): All Area: Combinations Original Author: Bentley Technical Support Group Problem: In order to evaluate the total load from operating conditions and…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 05. How to change the order / sequence of listed combinations in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2016 10.01.00.09 Problem…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 04. How to modify existing User defined combination names in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov. 2016 10.01.00.09 Problem…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 17. Why are results for a combination subtracting dynamic load cases (ex. GRT1P1 +U1 -S1 -R1) higher than when adding the same dynamic load cases (ex. GRT1P1 +U1 +S1 +R1) in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version April. 2018 11.03.00.08 Problem: Why are results for a combination subtracting dynamic load cases (ex. GRT1P1 +U1 …
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • General questions not covered by AutoPIPE's Code / Non-Code combination WIKI pages

    Mike Dattilio
    Mike Dattilio
    1. Default Code and Non-Code Combinations in an AutoPIPE model 2. User Combinations as a Template for the Next Model User code or non-code combinations created in the program can be used as a template for other models with the same analyzed load cases…
    • 10 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Default Code and Non-Code Combinations in an AutoPIPE model

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): All Area: Settings Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem: How…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "Code Comb" tab Questions

    Mike Dattilio
    Mike Dattilio
    The "Code Compliance" grid displays the combination set defined for piping code compliance (both the default combinations and user-defined sets). Any default code combination may be modified, deleted or reset and any new user combination created and modified…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 18. Why is there no sustain Code combination with Gravity, Pressure, and Temperature in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2017 11.01.00.17 Problem…
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. When creating a new AutoPIPE User defined combination on the Code Comb tab, is the order of the load cases / combinations of any consequence?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL Area: combination Original Author: Bentley Technical Support Group Date Logged & Current Version May 2015 09.06.02.06 Problem: When…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 13. How to see non-code information on Code combinations using AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Combination Original Author: Bentley Technical Support Group Date Logged & Current Version Nov…
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki