• 22. SAM cases are not included in AutoPIPE's code combination 2Mb2+ 2Mce, only the seismic force are being evaluated, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Cod combinations Date Logged & Current Version Aug. 2021 12.06.00.48 Problem: SAM cases are not included in the 2Mb2+2Mce code combination. Solution:…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 25. How are the seismic load is calculated in AutoPIPE Vessel?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: REport Date Logged & Current Version April 2020 41.04.00.013 Problem: How are the seismic load is calculated in AutoPIPE Vessel? Solution: The…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 02h. "Snow Load" - AutoPIPE Load Case

    Mike Dattilio
    Mike Dattilio
    The Snow Load dialog gives the user the ability to apply snow loads to segments of the model. When snow is applied, AutoPIPE creates a load in direction of gravity (simulating the real effects of snow in direct contact on a pipe), and can be defined through…
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 09. What to do when dynamic Response Spectrum exceeds a code allowable when using AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Reports Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2017 11.00.00.22 Problem: What to do when dynamic Response…
    • over 5 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel