Answer:
These values are not user input values or calculated values by the program. These values are referenced by the Allowable Bolt Load table at Room Temp or At Design Temp for the clamped flanges.
One can review the referenced table in AutoPIPE…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Date Logged & Current Version
Dec 2022 12.08.03.015
Problem:
How to calculate Von Mises category combinations allowable using AutoPIPE?
Solution:
Open…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Calculations
Date Logged & Current Version
June 2022 12.08.00.063
Problem:
How to calculate ASME B31.3 2010 Allowables in AutoPIPE?
Solution:
ASME B31…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
V8i, CONNECT
Environment:
N/A
Area:
Analysis
Subarea:
Original Author:
Bentley Technical Support Group
Date…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Report
Date Logged & Current Version
April. 2014 09.06.00.19
Problem:
Regarding the LCC (Load Controlled condition) check according to DNV 2012 (section…
Applies To
Product(s):
AutoPIPE
Version(s):
ALL;
Area:
Reports
Original Author:
Bentley Technical Support Group
Date Logged & Current Version
Feb. 2017 11.00.00.22
Problem:
What to do when dynamic Response…
Applies To
Product:
AutoPIPE
First Affected Version:
08.06.00
Found in Version:
09.01.01.02
Fixed and Released in Version:
09.03.00.08
Area:
Calculations
Severity:
Critical
…
Applies To
Product:
AutoPIPE
First Affected Version:
09.01.00
Found in Version:
10.00.00.10
Fixed and Released in Version:
10.01.00.08
Area:
Calculations
Severity:
Critical
…
Applies To
Product:
AutoPIPE
First Affected Version:
09.04.01
Found in Version:
09.04.01.05
Fixed and Released in Version:
09.05.01.02
Area:
Calculations
Severity:
Critical
…
Applies To
Product(s):
AutoPIPE
Version(s):
2004, XM, V8i, CONNECT;
Environment:
N/A
Area:
Original Author:
Bentley Technical Support Group
Date Logged & Current Version
Aug. 2016 10.01.00.09