• 46. What methods are used to calculate the K factor from ASME VIII Div 1, appendix EE for use in a Pressure Vessel designed in AutoPIPE Vessel?

    Mike Dattilio
    Mike Dattilio
    Answer: Given the vessel is 6040mm dia with a wall thickness = 20mm and Limpet / Half pipe coli with a pitch of 150 mm and 40 mm radius. Referencing, ASME VIII Div 1, appendix EE, figure EE-2 (DN80), the K factor would be read, but parameter D is…
    • 11 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. How AutoPIPE Vessel Calculate Corrosion Allowances as UG- 45 or ASME VIII div.1?

    Tanaji Gaikwad
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: General FAQ Date Logged & Current Version March 2019 41.00.00.006 Problem: How AutoPIPE Vessel Calculate Corrosion Allowances as UG- 45, ASME VIII…
    • 2 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. Does the calculation of a body flange according to ASME VIII, div 1, consider a rigidity criterion in an AutoPIPE Vessel model?

    Tanaji Gaikwad
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Report Date Logged & Current Version June 2018 40.06.00.07 Problem: Does the calculation of a body flange according to ASME VIII, div 1, consider…
    • 2 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?

    Tanaji Gaikwad
    Tanaji Gaikwad
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Calculations Date Logged & Current Version Sept. 2017 40.04.00.08 Problem: Formula for calculation of hydro-test pressure as per CODAP Div.1 is: …
    • 2 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 07 How does AutoPIPE Nozzle determine values of Kc, Cc, KL and CL corresponding to values of gamma and beta (B1/B2 and B2/B1)?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Nozzle Version(s): ALL; Area: Results Date Logged & Current Version Feb 2020 08.11.08.35 Problem: Questions about determine values of Kc, Cc, KL and CL 1 : How does the program…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Q. When Int. press ration >1.0, does this mean that the Flange failed in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Flange Date Logged & Current Version Dec 2019 12.02.00.14 Problem: When Int. press ration >1.0, does this mean that the Flange failed? Solution: A…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • AutoPIPE Known issue - Defect 1054789

    Mike Dattilio
    Mike Dattilio
    Applies To Product: AutoPIPE First Affected Version: 09.04 Found in Version: 11.04.00.10 Fixed and Released in Version: 12.02.00.14 Area: All Severity: Critical Backlog…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel