• 06. Confirm calculation of Flange dia with specified tolerance and corrosion settings using AutoPIPE Vessel

    Tanaji Gaikwad
    Tanaji Gaikwad
    Example: In the flanges of this equipment, a 1 mm tolerance and 1 mm corrosion margin have been indicated, but in the calculations, the thickness "corroded dimensions" only subtracts 1 mm, for example, flange 20.04, nominal thickness 40 mm, calculation…
    • 2 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. Flange calculations does not consider corrosion allowance and the flange facing height in AutoPIPE Vessel, why?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Date Logged & Current Version July 2020 41.05.00.008 Problem: In the ASME B16.5 flange calculation (welding neck type) the software does not deduct…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • W2164-204: The following flange(s) do not consider corrosion... warning message occurred in AutoPIPE, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Warning Date Logged & Current Version Feb 2020 12.02.00.14 Problem: The following is displayed when using AutoPIPE * * * W A R N I N G - MODEL * * * W2164…
    • over 1 year ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More