• W2182-26: Pressure rating on mating flange to a valve is not the same at point xxxx warning message displayed in AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Warning Message Original Author: Bentley Technical Support Group Date Logged & Current Version June. 2017 11.00.00.22 Problem: The following warning…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Q. ANSI Check Flange Loading Calculations, for some load cased Operating pressure appears to not be added to Equivalent pressure in AutoPIPE, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version April 2020 12.03.00.17 Problem: ANSI Check Effective flange pressure equals P operating plus P eq. For a number of load cases…
    • 8 months ago
    • AutoPIPE
    • AutoPIPE Wiki
  • N729-2: Specified load range overlies a valve and/or flange, check pressure rating...note message appears in AutoPIPE, why?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Note Message Date Logged & Current Version Nov. 2017 11.01.00.23 Problem: The following note message appears in AutoPIPE: -------------------------…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel