• 13. If dc = D2 was applicable to calculate λc only, can this relationship also be apply to equation 49 of GOST R 52857.3 n AutoPIPE Vessel?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version Oct. 2017 11.01.00.23 Problem: Per GOST P 52857.3 Does the program calculate Eq.49 using dc = D2? Solution: No,…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "GOST (Russian National Standards)" Piping Code Enhancements & Defects for AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Note: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. The following enhancements…
    • over 6 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 3. What Russian codes are certified for use in AutoPIPE?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Version(s): ALL Area: Codes Original Author: Bentley Technical Support Group Date Logged & Current Version Apr. 2016 10.01.00.05 Problem: What Russian…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • "RD 10-249-98" - Piping Code Enhancements & Defects for AutoPIPE

    Mike Dattilio
    Mike Dattilio
    Note: if an enhancement or defect has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program. The following enhancements…
    • over 4 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 14. What fatigue calculations are performed in AutoPIPE Vessel?

    JamieP
    JamieP
    Ans: Fatigue Analysis is performed according to the Code (simplified method),: ASME VIII Division 2 part 5 CODAP part C11 AD S1 EN 13445-3 part 17 GOST R 52857.6 PD5500 Annex C The user must have purchased the relevant license for the…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 05. When designing based on GOST code where a nozzle joint efficiency of 0.9 but in the report the joint efficiency is considered as 1. When running the same model changing the design code to ASME, the report shows joint efficiency=0.9, Why?

    JamieP
    JamieP
    Answer: The setting for the nozzle joint efficiency for eg. nozzle 'D' in question is as follows in the nozzle dialog box: As shown above the joint efficiency has been set as 0.9. In the report it is 1.0: This is because ASME and GOST have…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel