Problem:
How to best model this type of pressure vessel weld.:
Welding of a ferrule…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
ALL
Area:
Reporting
Date Logged & Current Version
July 2023 43.01.01.011
Problem:
How to add a multiple saddle in horizontal pressure vessel?
Example: …
Example of report:
Answer:
The first criteria in red (l c (sin a ) / r 2 ) is a limit of application based on the unsupported length of conical shell (lc) and the apex angle (a) and the radius at the large base (r 2 ), it must be < 0.8 to met the…
Answer:
Given the vessel is 6040mm dia with a wall thickness = 20mm and Limpet / Half pipe coli with a pitch of 150 mm and 40 mm radius.
Referencing, ASME VIII Div 1, appendix EE, figure EE-2 (DN80), the K factor would be read, but parameter D is…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
ALL
Area:
modeling
Date Logged & Current Version
July 2020 41.05.00.008
Problem:
How to add a skirt to a vessel?
Solution:
Select the vessel and select…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
ALL
Area:
Modeling
Date Logged & Current Version
Sept 2018 40.07.00.007
Problem:
Why the calculation of bolts is set by default on the dialog and then imposed…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
ALL
Area:
Calculation
Date Logged & Current Version
June 2018 40.06.00.07
Problem:
Found the following issues on the baseplate calculations from the output…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
V8i
Environment:
N/A
Area:
Modeling
Original Author:
Bentley Technical Support Group
Date Logged & Current Version …
01. How to optimize Body flange design in AutoPIPE Vessel?
02. Number of bolts required for design using AutoPIPE Vessel
03. On Body flange tab, why the calculation of bolts is set by default on the dialog and then imposed by the code to calculate…