• 12. How can I insert the shell connection on the head of a heat exchanger in AutoPIPE Vessel?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): V8i Environment: N/A Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version August 2016 40.02.00.08 Problem…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. Local Axis system load values do not appear to match WRC Axis system values in AutoPIPE nozzle output report?

    Mike Dattilio
    Mike Dattilio
    Applies To Product(s): AutoPIPE Nozzle Version(s): V8i Environment: N/A Area: Report Original Author: Bentley Technical Support Group Date Logged & Current Version Aug. 2016 08.11.08.26 Problem…
    • over 2 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Error Code 52 - WRC 107-297: Local Load Error

    JamieP
    JamieP
    WRC local load analysis method is based off of analytical and experimental data and is only applicable for certain specific range of the ratios of the geometric parameters of the vessel eg. vessel wall thickness, nozzle thickness, nozzle diameter and…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel