Applies To
Product:
AutoPIPE
First Affected Version:
09.04
Found in Version:
11.04.00.10
Fixed and Released in Version:
12.02.00.14
Area:
All
Severity:
Critical
Backlog…
Answer.
Please make sure that the field "Div. 2" is checked on the Design Parameters tab under Vessel Properties in order to run fatigue calculations and display in the report: