Answer:
This can be done using a jacketed vessel design module that exists in AutoPIPE Vessel.
Vacuum pressure can be applied as ‘0’ external pressure on the inner vessel (chamber 2) and as ‘0’ internal design pressure for the outer vacuum chamber…
Answer:
That seems normal, taking into account that your heat exchanger is requested to use the internal diameter (see general geometry dialog)
The input for the shell is 8 inch NPS
Normally an 8 inch NPS pipe has an external diameter of 8.625…
01. When choosing a 8" nominal shell size the O.D. is reflected as 8.78" O.D. (it should be 8.625").
02. How to import Aspentech edr file into AutoPIPE Vessel?
03. For a shell and tube exchanger with fixed tubesheets, the AutoPIPE Vessel is locked…