• 05. How to manage the number of Tubesheets in an AutoPIPE Vessel heat exchanger

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version July 2018 40.06.00.07 Problem: How to manage the number of Tubesheets in a heat exchanger Solution: The…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 06. How to see the pass order number and how to change it in an AutoPIPE Vessel model?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version June 2018 40.06.00.07 Problem: How to see the pass order number and how to change it? Solution: Use the…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • 03. For a shell and tube exchanger with fixed tubesheets, the AutoPIPE Vessel is locked with the "Mechanical cleaning" option even if the option is unchecked?

    JamieP
    JamieP
    Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version June 2018 40.06.00.07 Problem: For a shell and tube exchanger with fixed tubesheets, the software is locked…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • Error Code 29 - Equivalent stress in the tubes exceeded

    JamieP
    JamieP
    Q. I am getting the following error messages: equivalent stress in the tubes exceeded longitudinal stresses in the tubes exceeded. How do I solve these issues? Ans: Please see the following wiki page: http://communities.bentley.com/products…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More
  • Cancel