Problem:
How to define shell length in different types of Heat Exchanger
Solution…
The pass partition plate for shell side and tube side can be edited by clicking on "Show Accessories List" icon in the Bundle Layout dialog box:
Then click on Partition Plates:
You can modify some dimensions and make edits on the following dialog…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
V8i
Environment:
N/A
Area:
Modeling
Original Author:
Bentley Technical Support Group
Date Logged & Current Version
August 2016 40.02.00.08
Problem…
Applies To
Product(s):
AutoPIPE Vessel
Version(s):
V8i
Area:
Modeling
Original Author:
Bentley Technical Support Group
Date Logged & Current Version
August 2016 40.02.00.08
Problem:
The user would want…
Answer:
As usual in AutoPIPE Vessel, the number of the chamber must be correct.
You must check that the components on the tubes side are in the chamber number 2.
Q. I am getting the following error messages:
equivalent stress in the tubes exceeded
longitudinal stresses in the tubes exceeded.
How do I solve these issues?
Ans: Please see the following wiki page: