• 02. Does AutoPIPE Vessel consider cone-shell junction as line of support for external pressure calculation?

    JamieP
    JamieP
    Answer: Yes, AutoPIPE Vessel automatically considers the cone-shell junction as line of support for external pressure calculations. If the junction is not sufficient then a stiffener is automatically added. This is clearly printed out in the report…
    • over 3 years ago
    • AutoPIPE
    • AutoPIPE Wiki
  • View related content throughout AutoPIPE
  • More