• 05. When designing based on GOST code where a nozzle joint efficiency of 0.9 but in the report the joint efficiency is considered as 1. When running the same model changing the design code to ASME, the report shows joint efficiency=0.9, Why?

    JamieP
    JamieP
    Answer: The setting for the nozzle joint efficiency for eg. nozzle 'D' in question is as follows in the nozzle dialog box: As shown above the joint efficiency has been set as 0.9. In the report it is 1.0: This is because ASME and GOST have…