• Importing a Steel Detail Neutral File in AECOsim/OpenBuildingsDesigner CONNECT Edition

    Arghyakamal Bhattacharya
    Arghyakamal Bhattacharya
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Environment: N/A Area: Import/Export Subarea: SDNF Problem Description 1.I have a .dat file & a .txt file from Prosteel/Prostructures…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Exporting a wall having an Opening in it from DGN to DWG?

    Alifur Mandal
    Alifur Mandal
    Product(s): OpenBuildings Designer Version(s): CONNECT Edition Environment: N/A Area: Import/Export Subarea: DWG Problem Description How to export a wall having an Opening in it from DGN to…
    • over 3 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Export to ISM of a File with multiple References

    Tathagata Saha
    Tathagata Saha
    Product(s): AECOsim Building Designer Version(s): V8i and CONNECT Edition Environment: N\A Area: Import/Export Sub Area: ISM Export Problem Description When a DGN file having one or more…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • IFC2x3 Does Not Include Walls If the Slab Penetration Extends Beneath Them.

    Robert DiMauro
    Robert DiMauro
    Product(s): AECOsim Building Designer Version(s): SS6, CONNECT Edition Environment: N/A Area: Import/Export Subarea: IFC Problem Description: If a slab penetration extends slightly underneath…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Editing an RFA Cell

    Steve Cocchi
    Steve Cocchi
    Product(s): AECOsim Building Designer Version(s): V8i SELECTseries 6, CONNECT Edition Environment: N/A Area: Import/Export Subarea: Other Problem An RFA Cell imports with a clearance volume solid…
    • over 4 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • List Type ID instead of Mark in Structural Report Spreadsheet

    Ranit Deb
    Ranit Deb
    Product(s): AECOsim Building Designer Version(s): 08.11.09.866/10.03.00.40 Area: Import/Export Subarea: User Defined Problem How to make changes in the macro's to prepare Structural Report Spreadsheet…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Sketchup Files Will Not Open or Display

    Robert DiMauro
    Robert DiMauro
    (36068 False) (36068 False) Product(s): AECOsim Building Designer Version(s): 10.02.00.35 Environment: N\A Area: Platform Tools Subarea: (36068 False) Problem I…
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • Slow Loading and Manipulation of IFC Files

    Robert DiMauro
    Robert DiMauro
    Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N/A Area: Import/Export Subarea: IFC Original Author: Robert DiMauro, Bentley Technical Support Group …
    • over 5 years ago
    • OpenBuildings | AECOsim | Speedikon
    • OpenBuildings | AECOsim | Speedikon Wiki
  • View related content throughout OpenBuildings | AECOsim | Speedikon
  • More
  • Cancel