LARS LFD Composite Prestressed Concrete Verification
Structure ID = 1311151
Member ID = G02
Checkpoint = 1.5
“U” denotes “Ultimate Moment”. The ultimate moment from the “Additional Section Data” is 7627.85 ft-kips.
The computation for Mu is…
LARS LFD Composite Prestressed Concrete Report Information
LARS checks the compression flange and tension for top and bottom for each checkpoint. This is performed because any checkpoint along a beam may be the location at which contraflexure occurs…
LARS Bridge has a standard prestressed concrete section library. This library is accessed in the same manner as the standard steel section library. Four different beam shapes are available in the library. They are:
1) (B)ox beams which may be solid…
Change a non-standard prestressed concrete section to a standard prestressed
This document contains instructions on how to select the prestressed concrete standard section library.
Open the concrete description from Description -> Member Shape Description…