• Calculating headloss through a hydrant lateral

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i (08.11.04.57 and later) Area: Calculations Problem How do WaterCAD and WaterGEMS calculate head losses through a hydrant lateral, when using the lateral option…
    • 8 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How to turn on and off dashed lines associated with taps or customer meters

    Jesse Dringoli
    Jesse Dringoli
    Product(s): SewerGEMS, StormCAD, CivilStorm, SewerCAD, WaterGEMS, WaterCAD, HAMMER Version(s): CONNECT Edition Area: Layout and Data Input Problem When a tap node is placed, a dashed line appears to show which link the tap…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How are flow results reported for a pipe when using taps and laterals on a customer meter element?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Editioin Area: Modeling Problem How is the flow in a pipe calculated when using taps and laterals with a customer meter element? Solution This will depend on the placement…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Disconnection error with hydrant connected to lateral

    Scott Kampa
    Scott Kampa
    Product(s): WaterCAD, WaterGEMS Version(s): CONNECT Edition Area: Layout and Data Input Problem Hydrants connected to a lateral link element are shown as being isolated/disconnected: "Node is not connected to, or is isolated…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Finding customer meters not connected via a lateral

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterCAD, WaterGEMS Version(s): CONNECT Edition Area: Modeling Problem Some of my customer meters elements are not connected to a pipe via a lateral link element. How can I identify such cases so they can be fixed…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Customer Meter Elements and the External Customer Meter Data Manager

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Area: Modeling Original Author: Scott Kampa, Bentley Technical Support Group Customer Meter Element Customer Meter elements provide…
    • 10 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How can I reduce the number of pipes in my model?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition, V8i Problem How can the number of pipes be reduced in a WaterCAD or WaterGEMS model? Solution - Skelebrator To reduce the number of pipes in a model try to combine…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using LoadBuilder to assign Customer Meters to the nearest pipe using taps and laterals

    Larry Abla
    Larry Abla
    Product(s): WaterGEMS, WaterCAD Version(s): CONNECT Edition Area: Modeling Introduction In earlier versions of WaterGEMS and WaterCAD, LoadBuilder could be used to assign Customer Meter elements to the nearest junction…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • View related content throughout OpenFlows | Water Infrastructure
  • More
  • Cancel