Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i (08.11.04.57 and later)
Area:
Calculations
Problem
How do WaterCAD and WaterGEMS calculate head losses through a hydrant lateral, when using the lateral option…
Product(s):
SewerGEMS, StormCAD, CivilStorm, SewerCAD, WaterGEMS, WaterCAD, HAMMER
Version(s):
CONNECT Edition
Area:
Layout and Data Input
Problem
When a tap node is placed, a dashed line appears to show which link the tap…
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Editioin
Area:
Modeling
Problem
How is the flow in a pipe calculated when using taps and laterals with a customer meter element?
Solution
This will depend on the placement…
Product(s):
WaterCAD, WaterGEMS
Version(s):
CONNECT Edition
Area:
Layout and Data Input
Problem
Hydrants connected to a lateral link element are shown as being isolated/disconnected:
"Node is not connected to, or is isolated…
Product(s):
WaterCAD, WaterGEMS
Version(s):
CONNECT Edition
Area:
Modeling
Problem
Some of my customer meters elements are not connected to a pipe via a lateral link element. How can I identify such cases so they can be fixed…
Applies To
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i
Area:
Modeling
Original Author:
Scott Kampa, Bentley Technical Support Group
Customer Meter Element
Customer Meter elements provide…
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition, V8i
Problem
How can the number of pipes be reduced in a WaterCAD or WaterGEMS model?
Solution - Skelebrator
To reduce the number of pipes in a model try to combine…
Product(s):
WaterGEMS, WaterCAD
Version(s):
CONNECT Edition
Area:
Modeling
Introduction