• Tips on Sewer Calibration

    Jesse Dringoli
    Jesse Dringoli
    Product(s): SewerGEMS, SewerCAD Version(s): CONNECT Edition, V8i Area: Modeling Authors: Tom Walski, Jesse Dringoli and Scott Kampa, Bentley Systems Background Currently SewerCAD and SewerGEMS do not have an automated…
    • 3 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using SCADAConnect Simulator

    Scott Kampa
    Scott Kampa
    Applies To WaterGEMS Version(s): 08.11.06.113 and higher Area: Modeling Original Author: Scott Kampa & Mark Pachlhofer, Bentley Technical Support Group This TechNote provides details on using the new SCADAConnect Simulator…
    • 3 days ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • SCADAConnect in SewerGEMS

    Jesse Dringoli
    Jesse Dringoli
    Applies To Product(s): SewerGEMS, SewerCAD Version(s): CONNECT Edition, 08.11.04.54 and greater Area: Modeling Original Author: Terry Foster, Bentley Technical Support Group SCADAConnect…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Will SCADA Results Publishing work with only OPC sources?

    Sushma Choure
    Sushma Choure
    Product(s): Bentley WaterGEMS, SewerGEMS Version(s): V8i, Connect Edition Area: Modeling Problem Description Will SCADA Results Publishing work with only OPC sources? Recommended Solution OPC is an interoperability standard…
    • over 1 year ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • How can I publish my computed model results to a SCADA HMI?

    Yashodhan Joshi
    Yashodhan Joshi
    Product(s): WaterGEMS Version(s): CONNECT Edition, 08.11.06.58+ Area: Output and Reporting Background Starting with V8i SELECTseries 6 of WaterGEMS, the user can publish computed model results to a SCADA HMI (Human…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Time tolerance setting in SCADAConnect Simulator

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, WaterCAD, HAMMER, SewerGEMS, SewerCAD, StormCAD, CivilStorm, PondPack Version(s): Varies Environment: N\A Area: Output and Reporting The time tolerance setting in the new SCADAConnect…
    • over 3 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • What date and time is used from a Real Time SCADA Signal?

    Jesse Dringoli
    Jesse Dringoli
    Product(s): Bentley WaterGEMS, WaterCAD Version(s): 08.11. Environment: N\A Area: Problem When using a Real Time Signal in SCADAConnect, what date / time does the program select from the data source…
    • over 7 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Using the SCADA Element for annotation and reporting

    Jesse Dringoli
    Jesse Dringoli
    Product(s): WaterGEMS, SewerGEMS, WaterOPS, SewerOPS Version(s): CONNECT Edition, V8i Area: Modeling SCADA Element The SCADA element is used to link model elements to external field data (from a SCADA system) so that model…
    • 11 months ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • Can SCADAConnect support a connection to ClearSCADA or other SCADA systems besides Citect?

    MPachlhofer
    MPachlhofer
    Applies To Product(s): Bentley WaterGEMS, Bentley WaterCAD Version(s): 08.11.04.57 Environment: N/A Area: Layout and Data Input Subarea: Original Author: Mark Pachlhofer…
    • over 8 years ago
    • OpenFlows | Water Infrastructure
    • OpenFlows | Water Infrastructure Wiki
  • View related content throughout OpenFlows | Water Infrastructure
  • More