Product(s):
Hevacomp Electrical Designer - Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
As part of the cable sizing calculation, short circuit fault currents…
Product(s):
Electrical Design - Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
When attempting to place annotation on a Connect schematic, a Run Time Error 6…
Product(s):
Electrical Designer - Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
In some instances, you may wish to select a 3 or 4-core cable for a single phase…
Product(s):
Hevacomp Electrical Designer
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
During the Connect calculation, I²t is derived for checking short circuit faults…
Product(s):
Bentley Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
Power factor calculations are very complicated and have an effect on all other aspects…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
A Runtime Error 76 initially occurs when attempting to add a new cable type ( 17th Edition…
We recommend bookmarking this page for easy access
Hevacomp final version is V8i SS1 SP10 (V8i SS1 CP3 (06/16)) Should you require assistance installing, please post any queries in the forum
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
When viewing or printing reports in the Connect program, the main body of the report appears…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
The project title is not being set correctly.
Solution
The reports won't reflect a new…
Product(s):
<Product name to go in here>
Version(s):
V8i (version number)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
The Spare Capacity fields are greyed out when board data is edited…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
Underground cables appear to be undersized when the calculation is run
Solution
You should…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Problem
When the system is calculated, expected large volt drops are not being reported
Solution…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
When specifying a special Supply type, you are required to enter a fault current.
Method…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
You may wish to rename a board or busbar in your schematic.
Method
Right click on the…
Product(s):
Hevacomp Electrical Designer
Version(s):
V8i
Environment:
N/A
Area:
Connect
Subarea:
Operation
Overview
Hevacomp Connect allows the maximum voltage drop to be set individually for…
Product(s):
Bentley Hevacomp
Version(s):
V8i (V26)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
After a Windows 10 update, the software may generate Run Time Error 482 when attempting to…
Product(s):
Hevacomp Connect
Version(s):
V8i (N/A)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Overview
When trying to open a Hevacomp Connect project you may come across the following message…
Product(s):
All Hevacomp Products
Version(s):
V8i (26)
Environment:
N/A
Area:
N/A
Subarea:
N/A
Introduction
After running a new installation of Bentley Hevacomp V26.06, a Run time error 76…