Error computing model in PondPack: "The maximum dimension exceeds limitation 32767 ..."


Product(s):PondPack
Version(s):10.02.00.01
Area:Calculations

Problem

When attempting to compute a model in PondPack, the following user notification appears:

"The maximum dimension exceeds limitation 32767 (the maximum value of a 16-bit integer)."

Solution

This may be due to a known issue related to the use of a very small time of concentration for one or more catchments, which can cause the internal calculations to exceed a limitation.

Check your catchment time of concentration values and their units for unreasonable values. For example in one case a Tc of 0.003 hours (10.8 seconds) caused this issue. Increase the Tc or manually add inflows and try again.

An improvement to the messaging and/or handling will be investigated for a future version (reference # 1242460)

See Also