Product(s): | PondPack |
Version(s): | 10.02.00.01 |
Area: | Calculations |
When attempting to compute a model in PondPack, the following user notification appears:
"The maximum dimension exceeds limitation 32767 (the maximum value of a 16-bit integer)."
This may be due to a known issue related to the use of a very small time of concentration for one or more catchments, which can cause the internal calculations to exceed a limitation.
Check your catchment time of concentration values and their units for unreasonable values. For example in one case a Tc of 0.003 hours (10.8 seconds) caused this issue. Increase the Tc or manually add inflows and try again.
An improvement to the messaging and/or handling will be investigated for a future version (reference # 1242460)