Q. "ANSI Flange Check" sub-report using Flange Analysis command in AutoPIPE


Applies To
Product(s):AutoPIPE
Version(s):2004, XM, V8i 
Area: Report
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Feb. 2015
09.06.01.10

Problem:

In 2 AutoPIPE models: one is with EN 13480 code & other is ASME B31.1 code, for the same piping route. We performed ANSI Flange check for both the models are the results of ANSI check comparison are shown:

why are the allowables set = 0.00 for the En13480 piping code model but are generated for the B31.1 model?

Solution:

As mentioned in the AutoPIPE help:

"....which contains the following data for the standard ANSI B16.5 and 16.47 flanges:

Therefore, confirm the Flange Rating is listed as one of the above values (i.e. !50, 300, etc..). All other flange Rating values not supported by the code will be ignored, thus Allowable values returned will be 0.00 as indicated in image above. 

See Also

"Flange Analysis" sub report

Bentley AutoPIPE