AutoPIPE CONNECT v12.08.01.010 - Read Me File


Applies To
Product(s):AutoPIPE
Version(s):ALL
Area:Readme
Date Logged
& Current Version
June 2022
12.08.01.010

Note:

1. Select Link here for Release notes

What is New & Changed in AutoPIPE®

The following outline identifies new features and enhancements in the AutoPIPE CONNECT Edition version 12.08.01.010.

AutoPIPE® Requirements

More detailed installation information can be found in the AutoPIPE Quick Start Guide.

Product Version

ProductAutoPIPE
Versionv.12.08.01.010
Language

English, Japanese, Polish, Chinese

Included Applications Versions

PCF Translatorv1.2.0.063
STRAITv6.0.0.16
ADL Pipev1.0.0.22
AutoPIPE Nozzlev8.11.8.38
OPIMv10.10.00.71
Connection Clientv11.0.3.25

Installation Requirements

CD drive or access to the Internet required for product installation. The minimum system configuration for installation:

Operating SystemMicrosoft Windows 8 Professional or higher
Microsoft Windows 8.1 Professional or higher (with KB2919355 Update)
Microsoft Windows 10 Professional or higher
.NET Framework

4.7.2

When installing the product through the installer program, the required components will be installed automatically. The contents of the Desktop Prerequisite Pack include:

Minimum Profile

The minimum recommended workstation profile for running AutoPIPE is:

ProcessorIntel Pentium IV or higher.
Memory1 GB recommended. More memory almost always improves performance, particularly when working with larger models.
Hard Disk1 GB free disk space (not including Restore Point space requirements).
Video Graphics CardAny industry-standard video card which supports OpenGL 3D graphics.
ProjectWise

ProjectWise Server 10.00.03.299 with ProjectWise Explorer 10.00.03.453,
ProjectWise Server 10.0.1.67 with ProjectWise Explorer 10.0.1.67,
ProjectWise Server 10.0.0 with ProjectWise Explorer 10.0.0.11 or higher,
ProjectWise Server 8.11.7 with ProjectWise Explorer 8.11.7.133 or higher,
ProjectWise Server 8.11.9 with ProjectWise Explorer 8.11.9,
ProjectWise Server 8.11.11 with ProjectWise Explorer 8.11.11.

OpenPlant Isometrics Manager

Connect Edition Update 10 - 10.10.00.71

Note: Users can use OpenPlant Isometrics Manager (OPIM) to review Stress Isometrics created by AutoPIPE without an entitlement for OPIM, provided they are opened from within AutoPIPE. Direct use of OPIM without an entitlement will log usage and may lead to charges. Click here for more information. 

PDF ReaderAdobe® Acrobat Reader 7.0 or greater

Download and Installation

See the AutoPIPE Quick Start Guide (..\Documents\Quickstart_AutoPIPE.pdf) for more information on downloading and installing AutoPIPE.

To complete the licensing process, you must have the appropriate roles assigned by your Site Administrator. If you have not been assigned these roles, you will need to obtain the name of your Site Administrator by submitting a Service Request at http://apps.bentley.com/srmanager/ProductSupport.

If you are experiencing problems logging into your Bentley account, please contact Bentley at 1-800-BENTLEY (1-800-236-8539). Outside the United States +1 610-458-5000.

Network Considerations - Network drives are only supported for data files.

- AutoPIPE software must be installed on a local client workstation.

- AutoPIPE data files (*.DAT) must have full read/write access to be opened and edited.

Applications Included in the Installation Package

AutoPIPE Standard, AutoPIPE Advanced, AutoPIPE Nuclear, and add-ons are installed from one executable.

Documentation

Program Help: Detailed feature information may be accessed directly from the calling application by selecting the Help command, or by pressing the Help button from any of the application dialogs. Be sure to explore the program Help for answers to your questions. A set of supplemental How To, Tutorial, and Reference Information documents in PDF format are provided in the Supplemental Documentation folder (Bentley AutoPIPE > Supplemental Information) of the main Program Help file (autopipe.chm). 

Tutorials: Documentation for AutoPIPE applications is provided online in the Adobe.pdf format. These files are accessible from the Help Menu. All documents can be browsed, searched, or printed with the Adobe Acrobat Reader. Information and how to download a FREE copy of the Adobe Acrobat Reader can be obtained from http://www.adobe.com/.

It is highly recommended that you obtain the latest version of the Adobe Acrobat Reader..

Piping Codes

This sections contains the list of piping codes, code editions supported and AutoPIPE license edition (Standard, Advanced or Nuclear) for which these items are supported.

Standard Edition Piping Codes

Piping CodeDescription
B31.1 PowerPower Piping
B31.3 Process PipingProcess Piping
B31.4 Liquid Trans.Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia and Alcohols
B31.8 Gas Trans. & Dist.Gas Transmission and Distribution Piping Systems
EN 13480European Piping Code for Metallic Industrial Piping
GeneralGeneral Piping Code
ASME B31J

Stress intensification factors, flexibility factors, and sustained stress factors used in B31 piping analysis 

Extra Codes Available in AutoPIPE Advanced Edition

AutoPIPE Advanced includes all codes available in AutoPIPE Standard, as well as the following codes.

Piping CodeDescription
CSA-Z662Canadian Standards Association, Oil and Gas Pipeline System
CSA-Z662 OffshoreCanadian Standards Association, Offshore Steel Pipelines
BS 806Design and Construction of Ferrous Piping Installations for and in Connection with Land Boilers
BS 7159Design and Construction of Glass Reinforced Plastics (GRP) Piping Systems for Individual Plants or Sites
SPC-2Swedish Piping Code, Method 2
TBK5-6General Rules for Piping, The Norwegian Pressure Vessel Committee
STOOMWEZENDutch Piping Rule D1101 of the Rules for Pressure Vessels
DNV OffshoreDet Norske Veritas, Rules for Submarine Pipelines

MITI 501

MITI 501 Class III Piping Code
KHKKHK E 012 Piping Code, Seismic Level 1 or 2 (Seismic Level 2 requires a KHK 2 Add-On license)
RCC-MFrench Piping Code for Power Industry
SNCTFrench Piping Code for Process Industry
SNIP Russian 2.05.06-85 Oil & GasRussian SNIP piping code for oil and gas
ISO 14692Petroleum and Natural Gas Industries - Glass Reinforced Plastics (GRP) Piping
B31.4 OffshoreOffshore Liquid Piping Systems
B31.8 OffshoreOffshore Gas Transmission
B31.12 Hydrogen Industrial PipingASME B31.12 Hydrogen Pipelines (Section IP)
B31.12 Hydrogen PipelinesASME B31.12 Hydrogen Pipelines (Section PL)

Extra Codes Available in AutoPIPE Nuclear Edition

AutoPIPE Nuclear includes all codes available in AutoPIPE Standard and AutoPIPE Advanced, as well as the following codes.

Piping CodeDescription
ASME NB NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 1 Components
ASME NC NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection NC, Class 2 Components
ASME ND NuclearBoiler and Pressure Vessel Code, Rules for Construction of Nuclear Power Plant Components; Division 1, Subsection ND, Class 3 Components
JSME PPC NuclearJSME S NC1: Rules on Design and Construction for Nuclear Power Plants, Class 2 Piping

How to Activate AutoPIPE®

Subscription Entitlement Service is Bentley's new licensing model, providing enhanced security and optimized value for your Bentley Subscriptions. It is integrated with Bentley's Identity Management System (IMS) and the Bentley CONNECT technology platform to allow near real-time reporting of usage, improved alert messaging to users and increased administrative capabilities to license administrators in your organization. It will not only give you more options to monitor and manage usage but also provide new, advanced licensing features that will enhance digital workflows.

Activation

With Subscription Entitlement Service, all users must be registered with Bentley's Identity Management System (IMS) and sign in to the CONNECTION Client to access Bentley applications. Product activation will now occur through user sign-in to the CONNECTION Client with a valid IMS ID associated with their account. User sign-in will replace traditional activation keys, offering enhanced security as administrators will be able to control which users have access to Bentley software. License entitlements are granted and maintained through Subscription Entitlement Service's Entitlement Management Service. By signing into the CONNECTION Client users can also find their organization's projects, download software updates, receive relevant notifications, and track their usage.

For extended offline scenarios beyond the offline period of products (i.e. usually seven days), Subscription Entitlement Service provides the capability to reserve or check out licenses - click here for further details.

Alerts

Subscription Entitlement Service features the new license alerts notifications that can be set by an organization's license administrators to let the users know when they reach a set usage threshold. These notifications will alert the users that if they continue to use the product, a term license may be issued. The user in such a situation has the choice to quit the application before a license is used or acknowledge that a term license may be generated and proceed with starting the application, based on what settings the administrator chooses.

Evaluation Only - No license information

The product will run in evaluation mode.

Go to www.bentley.com to request activation information. 

Silent Installation

For SES Licensing:.

AutopipeSetup.exe -s -LicenseType=Connect 

Error History

The following outline identifies all major errors fixed in Release of AutoPIPE v12.8.1.

When pressure temperature data is modified for one point, the program randomly modifies the data for other point(s) as well. The issue is that multiple points share the same record of pressure temperature data; therefore, modifying data for one point results in the modification of all points that share that record.

The following outline identifies all major errors fixed in Release of AutoPIPE v12.8.

For ASCE 2010 seismic code, the program is incorrectly fetching the values of Mapped Spectral Response (Ss) from the database file USMapSsS1.mdb against the provided latitude/longitude values.

The Flange Summary report when produced using Quick Reports output (Result > Quick Reports > Output Report) displays the stress ratio for flanges with ANSI check enabled as zero. This only occurs when the second flange at a node has ANSI check enabled. If both the flanges on a node, or the first flange on the node has ANSI check enabled, the result summary is displayed correctly. Moreover, this issue cannot be reproduced when the Flange method is set to other than ANSI check.

Using copy/paste operation for a selection set having piping points with soil applied may result in unintended changes in the model where the selection set is pasted. This issue extends to the Insert Model option. The copy paste operation may be performed in the same model or in another model. The unintended changes in the model input data may lead to unintended results, which may be unconservative.

The in-plane and out-of-plane SIFs defined in the 'Joint Type and User SIFs' dialog with the 'Override SIF' checkbox checked are not multiplied by 0.75 as required by the ASME B31.3 and B31.12 codes. This may lead to higher stresses being reported for sustained and/or occasional load combinations. This issue does not affect models with 'Use B31J' checkbox checked in General Model Options.

Time history location dialog was not accepting beam points. Fixed now so that the dialog accepts beam points too.

A user interface inconsistency may lead to gasket material and gasket configuration of a flange to be reset when the Flange Check dialog is closed and reopened. Also, checking the Auto Flange/Bolt/Gasket dimensions box.

This issue is only in input grid. When "Peak Ground Velocity" value is updated from "Soil ID" grid, program updates "Peak Ground Acceleration" value instead of "Peak Ground Velocity". The value of "Peak Ground Velocity" remains the same.

A bug in the input grid and when switching model code to B31.3 was preferring critical temperature equation over the weld factor table when automatically calculating the longitudinal weld factor in Pipe Properties.

An error in AutoPIPE's Flange Analysis Summary output report (SQO) omits certain flanges. This is caused by flanges that were introduced on a node after one or more non-flange extra data components are added to that node.

The "Pressure Correction for User SIF" checkbox in result model options is used to apply the pressure correction factor as defined by ASME B31 codes to user-defined stress intensification factors. This option is disabled by default. Pressure Correction for User SIF is only available for ASME B31 codes for all available editions. User-defined stress intensification factors are inserted in the model using "Insert > Xtra Data > Joint Type & User SIF". If user-defined stress intensification factors are inserted on a bend with "Override all other In-plane and Out-plane SIFs at this point" checked and "Pressure Correction for User SIF" result model option checked, depending on the pressure value and dimension of the bend, pressure correction factor can significantly decrease the stress intensification factor (i) for the bend to less than 1.0 (SIF values should not be less than 1) which may lead to unconservative bend stress values.

Effective Diameter of Bolts maybe incorrectly used based on Auto Flange/Bolt Dimensions box state in flange check. This bug is valid for all piping codes with definition of new flanges. All analysis methods for flange in program maybe impacted except ANSI check (as Effective bolt diameter not used).

This issue is limited to bend points in B31.3 piping code models. The Result Model Options 'Set Occasional SIF = 0.75i' is not applied on bend points when the 'Use B31J' option is checked. The full SIF value is used instead of reducing the SIF by 0.75.

Copyright

TRADEMARK NOTICE

Bentley, the "B" logo, AutoPIPE, MicroStation, ProjectWise, SELECT, and MDL are either registered or unregistered trademarks or service marks of Bentley Systems, Incorporated, or one of its direct or indirect wholly-owned subsidiaries. Other brands and product names are trademarks of their respective owners.

COPYRIGHT NOTICE

© 2022, Bentley Systems, Incorporated. All Rights Reserved.

Including software, file formats, and audiovisual displays; may only be used pursuant to applicable software license agreement; contains confidential and proprietary information of Bentley Systems, Incorporated and/or third parties which is protected by copyright and trade secret law and may not be provided or otherwise made available without proper authorization.

Complete copyright information can be found in the product by choosing Help > About.

For reference, a copy of the End User License Agreement named "EULA.pdf" is included in the "AutoPIPE CONNECT v12" folder of the product installation. By default, this location is "C:\Program Files (x86)\Bentley\AutoPIPE CONNECT v12".

Corporate Headquarters    

Bentley Systems, Incorporated
685 Stockton Drive
Exton, PA 19341, United States
1-800-BENTLEY (1 800 236 8539)
Outside the United States
+1 610 458 5000

Bentley EMEA

Bentley Systems International Limited
Charlemont Exchange
5th Floor, Charlemont Street
Dublin 2, D02VN88, Ireland
1800 948 368
+353 1 436 4600

Bentley Asia

Bentley Systems (Beijing) Co., Ltd.
Unit 1402-06, Tower 1
China Central Place
Beijing 100025, China
400 842 7516
+86 10 5929 7000

See Also

AutoPIPE CONNECT Release Notes (10.00.xx.xx - higher)

How do I download, install, and license AutoPIPE?

Bentley AutoPIPE