Q. Modeling flanges as one point does it affect the flange leakage calculation?


Applies To
Product(s):AutoPIPE
Version(s):ALL
Area: Flange Analysis
Date Logged
& Current Version
Nov 2023
23.00.00.230

Problem:

Modeling flanges as one point does it affect the flange leakage calculation?

Solution:

Answer is No, There will be no impact on flange design and flange rigidity check even if we model flange as single point.

While performing flange check we provide all the dimensional and material properties of flange, bolt, gasket to the flange in flange check module.

See below image for example,

Flange:

Bolt: 

Gasket:

Even though we model the flange as single point, while performing the flange check we give all the details required for the flange design and flange rigidity check.

See Also

Flange Analysis

"Flange Analysis" sub report

Bentley AutoPIPE