How to fix the disconnects with a selection from the spec grid.



Applies To 
Product(s):OpenPlant Modeler CE U9
Version(s):

CONNECT Edition 10.09.00.74 

Environment: Windows 10 (64-bit)
Area: User Interface
Subarea: 
Original Author:Jayu Bhosale, Bentley Product Advantage Group

Background

In OpenPlant Modeler CE, due to certain reasons connectivity of the connected component is lost. This wiki article will help to fix the disconnects with a selection from the spec grid.

Steps to Accomplish

  1. Launch OPM CE and select the components to be fixed.



  2. Run connectivity checker. Go to Piping Tab > Piping Network > Click on Connectivity.



  3. A Connectivity Checker dialogue box will popup showing the Missing fasteners as shown.



  4. To fix disconnets or fastener here with selection from spec grid. Click on Show Spec Grid icon and click Fix Disconnects button as shown. 



  5. Spec grid will appear if more than one result is encountered in spec to choose bolts.