Error Messages


Error Code 032768 - Program has encountered an error and will close now

Error Code 25 - Insufficient strength in shell/channel joint

Error Code 27 - Longitudinal membrane stress in the tubes exceeded

Error Code 28 - Longitudinal membrane stress in the shell exceeded

Error Code 29 - Equivalent stress in the tubes exceeded

Error Code 52 - WRC 107-297: Local Load Error

Error Code 89 - Allowable stress at temperature missing (95C)

Error Code 98 - Unable to design geometrical plate layout without interference

Error Code 113 - Tubesheet: modulus of elasticity at temperature missing (330 °C)

Error Code 151 - Design Code required isn't part of your license (ASME)

Error Code 181 - Cone 3: should be placed between 2 shells

Error Code 182 - No face detail on flange with gasket on both side of the bolt circle

Error Code 235, 236, 237 - Floating Head (split ring): allowable stress

Error Code 243 - FLOATING HEAD (crown): modulus of elasticity at ambient temperature missing.

Error Code 287 - Error in formula [40*bd] for gasket according to AD B7

Error Code 316 - PD 5500 Figure G.2.2-18 deflections of cyl. shells due to radial loads, values beyond curve boundaries

Error Code 331 - NOZZLE N1: Weld sizes are not adequate

Error Code 334 - Tubesheet: Design code required ins't part of your License (ASME)

Error Code 356 - Gasket width insufficient ( minimum=##.### mm ), the permissible gasket load is exceeded, use of a compression ring is recommended

Error Code 404 - Flange xx.xx seating pressure less than or equal to zero

Error Code 411, 412 - Nozzle AP (pad) allowable stress at temp missing, exceptional ambient allowable stress missing

Error Code 417 - Insufficient reinforcement

Error Code 425 - Floating Head (split ring/splices): insufficient thickness or gap not maintained

Error Code 490 - FLAT HEAD: number of opening > 1 ==> out of the scope (the calculation has been made with the opening giving the greater thickness). Use an other code ( EN 13445-3 or BS/PD5500 ).

Error Code 515 -FLANGE 30.02 : insufficient flange thickness (design case No. 0).

Error Code 538 - ADJACENT OPENINGS (nozzles C/D): nozzles are too close to one another ( 43.785 mm < 50 mm ).

Error Code 593 - Saddle effective angle < 30Deg (blast int Max P (Corroded inertias) (Corroded Weight), revise design of vessel

Error Code 633 - The tube-to-Tubesheet joint strength is not adequate

Error Code 677 - Conical Shell (XX.XX.XX) Under Internal Pressure: U-2(g) analysis is required or provide a flare at the small junction of the conical shell (Appendix 1-5(e))

Error Code 772 ROOF: Insufficient Support Column.

Error Code 773 ROOF: Insufficient Rafter.

Error Code 795 - API 650: design temperature >93 deg C.

Error Code 811 ROOF: Insufficient Girders.

Error Code 885 - Tubesheet: tubesheets gasketed with shell are not possible for a fixed tubesheets heat exchanger

Error Code 998 - Local Loads: Beyond curve boundaries (WRC 537 cannot be applied)

Error Code 77832 - Abnormal Termination message appears when starting AutoPIPE Vessel 

IDispatch::Invoke("LoadArx"=00000013) failed w/err 0x80020009

Not a valid Material Database

Unknown Procal Release - Release 1

Error - How to resolve "Output results required" error in AutoPIPE vessel?

Error - How to resolve "Timeout Exceeded (3600 s)" error in AutoPIPE vessel?

See Also