"Error" messages displayed in AutoPIPE


  1. AutoPIPE Preview Handler error on installation

  2. Closed loop detected in imported model at TEE point XXX.

  3. E13-16: Cannot Find the specified units file

  4. E13-63: Invalid code material(s) detected. 

  5. E15-13: PXD file is needed for accessing AutoPLANT data in this model Please place PXD and PXH files in same directory as DAT file.

  6. E15-34: Select Material library does not match

  7. E21-40: Executing this operation can corrupt distributed load records in AutoPIPE

  8. E31-37: Material type not recognized. Re-enter

  9. E36-42:   Tie/Link must be connected to another point

  10. E36-43: Connected point cannot be the current point

  11. E36-70: Cost must be greater than zero

  12. E38-95: Cannot insert component after a tee

  13. E39-27: Zero length not permitted

  14. E40-100: ASME B31J requires angle to be greater than 5.0 deg and less than 60 deg

  15. E54-79: No Joint Type & User SIF at the selected location(s)

  16. E90-21: Analysis results do not exist 

  17. E90-35: AutoPIPE Nozzle not installed

  18. E90-43:   Structural Synchronizer not installed on the system.

  19. E102-155: This point must be an anchor/reference point

  20. E102-161: This point does not have reference point defined

  21. E119-1: Maximum number of load combinations exeeded

  22. E131-30: AUTOPIPE.CLR not found

  23. E154-16: This value must be between 0 and 2, recommended value is 0.5

  24. E156-38: Value must be greater than zero

  25. E175-28: Error in velocity profile specification

  26. E221: Please contact Rebis

  27. E511-1: Invalid AutoPIPE data file

  28. E512-65: the model cannot be opened

  29. E512-109 cannot open Projectwise model

  30. E512-149: Model name must not contain space character before extension

  31. E514-2: Unable to retrieve Time History Load and Time History files

  32. E516-8: Demo version limit of 20 points exceeded

  33. E516-11: Analysis terminated: model must have more than one point

  34. E516-89: Program has failed to validate your SELECT subscription

  35. E521-22: Base point is not on selected range

  36. E521-24: No range specified for copying

  37. E522-32: Cannot find clipboard file in current directory

  38. E522-33: Cannot complete the paste operation

  39. E523-21: No Range specified for rotation

  40. E527-25: Point not found in selected range

  41. E723-23: System is not complete for analysis purposes

  42. E726-104: Zero length not allowed at beam XX

  43. E732-1: Angle is 0 deg. at bend xxx

  44. E732-2: Angle is 180 deg. at bend xxx

  45. E732-3: Not enough clearance to fit bend xxx

  46. E737-26: Valve components are not permitted in HDPE pipe system as per CC N-755-1

  47. E751-1 Tee type gt 8 or lt 1. SIF not calculated

  48. E753-18 Cannot be reducer face

  49. E774-44: Equation requires more combinations to be complete

  50. E801-1: FATAL ERROR: Unstable System

  51. E801-3: No static load cases specified

  52. E801-4: Zero length element

  53. E801-5: Zero Element Stiffness in AutoPIPE

  54. E801-6: Zero flexible length beam

  55. E801-11: Fatal Error: no mass in the system

  56. E801-12: Cannot find next frequency

  57. E801-24: Number of MSRS groups is inconsistent with SAM case - Error Message in AutoPIPE

  58. E801-62: Unable to process any time history function

  59. E801-64: Undefined point name in time history load data

  60. E801-75: Cannot allocate memory for analysis, unload some applications.

  61. E801-77: Multiple use of same THP file name at a point. May copy and rename

  62. E801-135: Number of analysis nodes exceeds maximum limit of 10000 nodes

  63. E829-1: Incorrect model size in file Static analysis results will be ignored.

  64. E951-1: No default available. Re-enter

  65. E951-3: Expecting real input. Re-enter

                  Answer: insert a valid value into the current field before selecting a different cell / OK button.
                  Example: Spaces at the end of "Line class", in PIPE ID properties.  

  66. E951-31: Cannot find or read autoplan.cnf file. Please reinstall the program.

  67. E962-1: File read error, please contact BENTLEY

  68. E962-2: File write error, check disk space

  69. E963-8: Non-ascii characters or "?" are not permitted in name

  70. E963-21: Number of characters in name cannot exceed 48

  71. E2164-15: Qualified stress for all bend and tee components should be greater than zero

  72. Error 1316 - A network error occurred while attempting to read from the file 

  73. LoadLibrary failed with error 87 

  74. LoadLibrary failed with error 1114: A dynamic link library (DLL) initialization routine failed

  75. No load case is selected to print time history results

  76. No Piping with OD >= 1.400 inches is found in PXF file 

  77. Program failed to generate C2 file

  78. "Root Element Is Missing"

  79. The model you are about to open as last modified in a newer version...

  80. Time history analysis file (*.TIM) does not exist.

  81. Error: could not initialize the DgnPlatform.

  82. Error: Input string was not in correct format.